Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 190(3): 98, 2023 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-36806988

RESUMO

Graphdiyne (GDY) has attracted a lot of interest in electrochemical sensing application with the advantages of a large conjugation system, porous structure, and high structure defects. Herein, to further improve the sensing effect of GDY, conductive MWCNTs were chosen as the signal accelerator. To get a stable composite material, polydopamine (PDA) was employed as connecting bridge between GDY and MWCNTs-NH2, where DA was firstly polymerized onto GDY, followed by covalently linking MWCNTs-NH2 with PDA through Michael-type reaction. The formed GDY@PDA/MWCNTs-NH2 composite was then explored as an electrochemical sensor for benomyl (Ben) determination. GDY assists the adsorption and accumulation of Ben molecules to the sensing surface, while MWCNTs-NH2 can enhance the electrical conductivity and electrocatalytic activity, all of which contributing to the significantly improved performance. The proposed sensor displays an obvious oxidation peak at 0.72 V (vs. Hg|Hg2Cl2) and reveals a wide linear range from 0.007 to 10.0 µM and a low limit of detection (LOD) of 1.8 nM (S/N = 3) toward Ben detection. In addition, the sensor shows high stability, repeatability, reproducibility, and selectivity. The feasibility of this sensor was demonstrated by detecting Ben in apple and cucumber samples with a recovery of 94-106% and relative standard deviations (RSDs) less than 2.3% (n = 5). A sensitive electrochemical sensing platform was reported for benomyl (Ben) determination based on a highly stable GDY@PDA/MWCNTs-NH2 composite.


Assuntos
Nanotubos de Carbono , Nanotubos de Carbono/química , Técnicas Eletroquímicas , Benomilo , Reprodutibilidade dos Testes
2.
Chin Med J (Engl) ; 129(22): 2647-2651, 2016 11 20.
Artigo em Inglês | MEDLINE | ID: mdl-27823994

RESUMO

BACKGROUND: The conventional venous access for cardiovascular implantable electronic device (CIED) is the subclavian vein, which is often accompanied by high complication rate. The aim of this study was to assess the efficacy and safety of optimized axillary vein technique. METHODS: A total of 247 patients undergoing CIED implantation were included and assigned to the axillary vein group or the subclavian vein group randomly. Success rate of puncture and complications in the perioperative period and follow-ups were recorded. RESULTS: The overall success rate (95.7% vs. 96.0%) and one-time success rate (68.4% vs. 66.1%) of punctures were similar between the two groups. In the subclavian vein group, pneumothorax occurred in three patients. The subclavian gaps of three patients were too tight to allow operation of the electrode lead. In contrast, there were no puncture-associated complications in the axillary vein group. In the patient follow-ups, two patients in the subclavian vein group had subclavian crush syndrome and both of them received lead replacement. The incidence of complications during the perioperative period and follow-ups of the axillary vein group and the subclavian vein group was 1.6% (2/125) and 8.2% (10/122), respectively (χ2 = 5.813, P = 0.016). CONCLUSION: Optimized axillary vein technique may be superior to the conventional subclavian vein technique for CIED lead placement. TRIAL REGISTRATION: www.clinicaltrials.gov, NCT02358551; https://clinicaltrials.gov/ct2/show/NCT02358551?term=NCT02358551& rank=1.


Assuntos
Veia Axilar , Veia Subclávia , Idoso , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Assistência Perioperatória , Pneumotórax/diagnóstico , Pneumotórax/etiologia , Complicações Pós-Operatórias , Implantação de Prótese/efeitos adversos
3.
Anal Biochem ; 500: 80-7, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26898304

RESUMO

In this article, a novel, label-free, and inherent electroactive redox immunosensor for carcinoembryonic antigen (CEA) based on gold nanoparticles (AuNPs) and Nile blue A (NB) hybridized electrochemically reduced graphene oxide (NB-ERGO) is proposed. The composite of NB-graphene oxide (NB-GO) was prepared by π-π stacking interaction. Then, chronoamperometry was adopted to simultaneously reduce HAuCl4 and nanocomposites of NB-GO for synthesizing AuNPs/NB-ERGO. The immunosensor was fabricated by capturing CEA antibody (anti-CEA) at this nanocomposite modified electrode. The immunosensor determination was based on the fact that, due to the formation of antigen-antibody immunocomplex, the decreased response currents of NB were directly proportional to the concentrations of CEA. Under optimal conditions, the linear range of the proposed immunosensor was estimated to be from 0.001 to 40 ng ml(-1) and the detection limit was estimated to be 0.00045 ng ml(-1). The proposed immunosensor was used to determine CEA in clinical serum samples with satisfactory results. The proposed method may provide promising potential application in clinical immunoassays with the properties of facile procedure, stability, high sensitivity, and selectivity.


Assuntos
Técnicas Biossensoriais , Antígeno Carcinoembrionário/análise , Técnicas Eletroquímicas/instrumentação , Grafite/química , Nanocompostos/química , Oxazinas/química , Microscopia Eletrônica de Varredura , Óxidos/química
4.
Biosens Bioelectron ; 62: 261-7, 2014 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-25022509

RESUMO

Most conducting polymer/graphene composites have excellent electrical conductivity. However, the background currents of these composites modified electrodes are much larger. In order to improve the sensitivities of these methods, it is necessary to decrease the background signal. In this paper, porous structure films of overoxidized polypyrrole/graphene (PPyox/GR) have been electrochemically coated onto glassy carbon electrode (GCE) and successfully utilized as an efficient electrode material for the quantitive detection of adenine and guanine, two of the most important components of DNA and RNA. The permselective polymer coatings with low background current could improve the selectivity and sensitivity of microelectrodes for the electropositive purine bases. The GRs into these polymers would further improve sensitivity by increasing the electroactive surface area. The electrochemical sensor can be applied to the quantification of adenine and guanine with a linear range covering 0.06-100 µM and 0.04-100 µM, and a low detection limit of 0.02 µM and 0.01 µM, respectively. More importantly, the proposed method was applied to quantify adenine and guanine in calf thymus DNA with satisfactory results.


Assuntos
Adenina/análise , Técnicas Biossensoriais/métodos , Guanina/análise , Nanocompostos , Animais , Técnicas Biossensoriais/estatística & dados numéricos , Bovinos , DNA/química , Técnicas Eletroquímicas , Eletrodos , Grafite/química , Concentração de Íons de Hidrogênio , Limite de Detecção , Microscopia Eletrônica de Varredura , Nanocompostos/química , Nanocompostos/ultraestrutura , Oxirredução , Polímeros/química , Pirróis/química , Reprodutibilidade dos Testes , Espectroscopia de Infravermelho com Transformada de Fourier
5.
J Interv Card Electrophysiol ; 28(2): 147-51, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20396938

RESUMO

OBJECTIVES: Focal atrial tachycardia (AT) arising from non-coronary cusp (NCC) is very rare, and the experience in catheter ablation of this kind of tachycardia remains limited. This study describes the electrophysiologic characteristics and radiofrequency ablation of AT arising from NCC. METHODS AND RESULTS: The study population consisted of five consecutive patients (three females and two males; age 37-68 years) with AT arising from NCC. The morphology of P waves was described as positive, negative, isoelectric, or biphasic (positive-negative or negative-positive). The atrial mapping was performed during tachycardia to define the earliest atrial activation site. Mean tachycardia cycle length of AT in five patients was 363 +/- 44 ms. P-wave morphology was predominantly upright or biphasic in lead II, III, and aVF, inverted in aVR. Positive P-wave morphology was seen in lead aVL in all five patients. The precordial leads were negative-positive in V(1) and V(2), negative-positive or positive in lead V(3)-V(5), and positive in lead V(6). All the five patients underwent successful radiofrequency ablation within NCC. During a follow up of > 3 months, no patient presented with a recurrence. CONCLUSIONS: This study demonstrated that mapping and ablation of focal AT arising from NCC is safe and effective. When earliest activation was recorded in the proximal electrode of the His-bundle catheter, but radiofrequency ablation in this region cannot successfully eliminated the tachycardia, the AT should be considered to arise from NCC especially when P-wave morphology was initially negative with a late positive component in right precordial leads, upright or biphasic in inferior leads.


Assuntos
Ablação por Cateter/métodos , Seio Aórtico/fisiopatologia , Seio Aórtico/cirurgia , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Atrial Ectópica/cirurgia , Adulto , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...